Installing the ARN/DC
116273-B Rev 00
1-27
Connecting to the DC Power Source
To connect the ARN/DC to the DC power source:
1.
Terminate the remote end of the three power input leads with #6 spade
lugs.
2.
Ensure that the DC power switch is in the lowered,
off
position (0)
(Figure 1-20)
.
Figure 1-20. DC Power Terminal Blocks and Power Switch
Danger:
Due to high-energy hazards, only qualified service personnel are
permitted to connect the ARN/DC to the power source.
Note:
Although AWG #18 wiring is adequate for the input leads, AWG #16 is
recommended to ensure minimal voltage drop from the power source.