Part No. 893-839-C
September 1996
Using the BayStack
100-series Hubs
893-839-CBook Page i Thursday, December 12, 1996 4:18 PM
Przeglądanie stron 0
1 2 3 4 5 6 ... 65 66

Podsumowanie treści

Strona 1 - 100-series Hubs

Part No. 893-839-CSeptember 1996 Using the BayStack 100-series Hubs 893-839-CBook Page i Thursday, December 12, 1996 4:18 PM

Strona 2

893-839-CBook Page xii Thursday, December 12, 1996 4:18 PM

Strona 3 - Bay Networks Customer Support

893-839-C 1-1 Chapter 1 Quick Reference Information Congratulations on your purchase of a BayStack ™ 100-series hub, a stackable Ethernet repeat

Strona 4

Quick Reference Information 1-2 893-839-C List of Features BayStack 100-series hubs have the following features:• 10 Mb/s Ethernet ports with the fol

Strona 5 - Contents

List of Features 893-839-C 1-3 • The BayStack 100-series Advanced Network Management Module (Advanced NMM) provides all of the features of the Stan

Strona 6

Quick Reference Information 1-4 893-839-C Hub Components This section describes the BayStack 100-series hub product line and their respective compone

Strona 7 - 893-839-C vii

Hub Components 893-839-C 1-5 Figure 1-3. Front panel of the BayStack Model 104 telco hubFigure 1-4. Front panel of the BayStack Model 105 fiber hubF

Strona 8 - -viii 893-839-C

Quick Reference Information 1-6 893-839-C 1 Media Adapter Slots Media adapter slots A and B are available for optional media adapter modules (see Fig

Strona 9 - 893-839-C xi

Hub Components 893-839-C 1-7 Table 1-3 shows the different connection options available using the communications port. For more information about t

Strona 10

Quick Reference Information 1-8 893-839-C 4 Ethernet Ports BayStack 100-series hubs provide 10 megabit per second (Mb/s) Ethernet ports in RJ-45, tel

Strona 11 - BayStack-specific Terms

Hub Components893-839-C 1-9 Telco 10BASE-TThe BayStack Model 104 telco hub has 24 10BASE-T ports through two 12-port telco connectors. Table 1-5 lists

Strona 12 - List of Features

ii 893-839-C © 1996 by Bay Networks, Inc. All rights reserved. Trademarks Optivity is a registered trademark of Bay Networks, Inc. Bay Networks, Bay

Strona 13 - 893-839-C 1-3

Quick Reference Information1-10 893-839-CTable 1-6 lists the pinouts for ports 13 through 24.Table 1-6. Telco 50-pin D connector pin assignments ports

Strona 14 - Hub Components

Hub Components893-839-C 1-11 ST 10BASE-FLThe BayStack Model 105 fiber hub straight-tip (ST) bayonet-type fiber optic cable connectors are compatible wit

Strona 15 - Cascade Up

Quick Reference Information1-12 893-839-C5 LED DisplayThe LED display (see Figure 1-8) indicates the segment assignments and the status of the ports,

Strona 16 - 1 Media Adapter Slots

Hub Components893-839-C 1-13 6 Power ConnectorBayStack 100-series hubs come in AC and DC power input options.AC Power ConnectorUse the AC power connec

Strona 17 - 3 MDI-X/MDI Port Button

Quick Reference Information1-14 893-839-CFor information about power specifications for the −48 V DC hubs, refer to Appendix A, “Technical Specification

Strona 18 - 4 Ethernet Ports

Hub Components893-839-C 1-15 Figure 1-9. Segment Select switch (default) and configuration modesAn NMM installed in a 100-series hub can be assigned th

Strona 19 - 12-port telco connectors. T

Quick Reference Information1-16 893-839-CFor more information about using the management extension ports, see “Extending Management to Remote Cascades

Strona 20 - 1-10 893-839-C

893-839-C 2-1 Chapter 2 Installing and Stacking BayStack HubsThis chapter outlines the procedures for installing a BayStack 100-series hub and the p

Strona 21 - ST 10BASE-FL

Installing and Stacking BayStack Hubs2-2 893-839-C1. To begin the installation process, install any optional media adapters and expansion slot modules

Strona 22 - 5 LED Display

Installing a BayStack Hub893-839-C 2-3 Figure 2-1. Forward and rear rack mount bracket positionsInsert the flat-head screws provided with the mounting

Strona 23 - 6 Power Connector

893-839-C iii Ordering Bay Networks Publications To purchase additional copies of this document or other publications for Bay Networks ™ products,

Strona 24 - 9 Segment Select Switch

Installing and Stacking BayStack Hubs2-4 893-839-CInstalling a Hub on a WallIn a wall installation, Bay Networks recommends that the 100-series hub be

Strona 25 - 40 meters 60 meters

Installing a BayStack Hub893-839-C 2-5 3. Holding the hub against the plywood, align the bracket holes with the pilot holes in the wood. 4. Insert flat

Strona 26 - 12 Expansion Slot

Installing and Stacking BayStack Hubs2-6 893-839-CInterconnecting Your StackThe cascade and management extension ports on each hub are designed to inc

Strona 27 - Installing Optional Modules

Interconnecting Your Stack893-839-C 2-7 To create a cascade of 100-series hubs, follow these steps:1. Connect one end of the cascade cable to the Casc

Strona 28 - Installing a Hub in a Rack

Installing and Stacking BayStack Hubs2-8 893-839-CFigure 2-5. LED display of hub and NMM segment assignments• Changes to the segment select switch ove

Strona 29 - 893-839-C 2-3

Interconnecting Your Stack893-839-C 2-9 Figure 2-6. Default position of the Segment Select switch is segment 1The Segment Select switch can be set in

Strona 30 - Installing a Hub on a Wall

Installing and Stacking BayStack Hubs2-10 893-839-CWhen you use the management extension ports to connect cascades, be sure to consider the following

Strona 31 - Completing the Installation

Verifying Your Installation893-839-C 2-11 • A standard straight-through UTP cable (MDI to MDI-X, as shown in Figure 2-8) is customarily used for conne

Strona 32 - Interconnecting Your Stack

Installing and Stacking BayStack Hubs2-12 893-839-C• Power is connected to all hubs in the stack.• The hub and any installed modules have completed th

Strona 33 - Choosing Segment Assignments

893-839-C 3-1 Chapter 3 Configuration Rules for BayStack HubsThis chapter provides network configuration and Ethernet compliance guidelines for BaySta

Strona 34 - 2-8 893-839-C

iv 893-839-C 893-839-CBook Page iv Thursday, December 12, 1996 4:18 PM

Strona 35

Configuration Rules for BayStack Hubs3-2 893-839-C• An optional NMM can be installed to provide network management for each segment in a stack. For mo

Strona 36 - 2-10 893-839-C

Network Configuration Decisions893-839-C 3-3 • The entire Ethernet network consists of only IEEE 802.3 components,Bay Networks host modules, hubs, and

Strona 37 - Verifying Your Installation

Configuration Rules for BayStack Hubs3-4 893-839-CNetwork Path Containing Five Repeaters In the longest path containing five repeaters, the following r

Strona 38 - Troubleshooting

Example of a Managed Multisegment Stack893-839-C 3-5 The three parts of the stack are operating in different rooms. The Accounting cascade is 60 meter

Strona 39 - 893-839-C 3-1

Configuration Rules for BayStack Hubs3-6 893-839-CTable 3-2 summarizes how the different elements in this stack are configured.Table 3-2. Example stack

Strona 40 - 3-2 893-839-C

893-839-C 4-1 Chapter 4 Operating a Stack of HubsThis chapter contains relevant information about your BayStack 100-series hub. The chapter includes

Strona 41

Operating a Stack of Hubs4-2 893-839-CSwapping a Hub in a StackTo swap a hub in a functioning stack, follow these steps:1. Disconnect the primary and

Strona 42 - 3-4 893-839-C

Using the Communications Port893-839-C 4-3 7. Verify your installation.See “Verifying Your Installation” on page 2-11.Using the Communications PortYou

Strona 43 - Example Summary

Operating a Stack of Hubs4-4 893-839-C2. If you are connecting to a modem, refer to the documentation included with your modem for the configuration pa

Strona 44 - 3-6 893-839-C

Using the Communications Port893-839-C 4-5 Troubleshooting a Communications Port ConnectionIf the startup diagnostic message does not appear on your c

Strona 45 - Automatic Hub Configuration

893-839-C v Contents Chapter 1 Quick Reference Information BayStack-specific Terms 1-1List of Features 1-2Hub Components 1-4RJ-45 10BA

Strona 46 - Swapping a Hub in a Stack

893-839-CBook Page 6 Thursday, December 12, 1996 4:18 PM

Strona 47 - Using the Communications Port

893-839-C A-1 Appendix A Technical SpecificationsThis appendix provides technical specifications for the BayStack 100-series hubs.Specifications for th

Strona 48 - 4-4 893-839-C

Technical SpecificationsA-2 893-839-CEnvironmental SpecificationsOperating temperature:Storage temperature:Operating humidity:Storage humidity:Operati

Strona 49 - 893-839-C 4-5

893-839-C A-3 Specifications for the BayStack Model 105 Fiber HubTable A-1 lists the maximum (total) distance allowed in the fiber connection for the mo

Strona 50

Technical SpecificationsA-4 893-839-CDeclaration of ConformityThe following Declarations of Conformity for the BayStack 100-series hubs comply with IS

Strona 51 - 893-839-C A-1

893-839-C B-1 Appendix B Connecting to a –48 V DC Power SourceThis appendix provides the relevant installation and reference information necessary f

Strona 52 - A-2 893-839-C

Connecting to a –48 V DC Power SourceB-2 893-839-C Safety ConsiderationsNOTE: Bay Networks recommends that you use crimp lug terminals that are UL lis

Strona 53 - 893-839-C A-3

893-839-C B-3 Attaching the DC Input Ground WireRequired tools: Crimping tool and flat-tip screwdriver1. Insert 6-gauge grounding cable into the ter-mi

Strona 54 - Declaration of Conformity

B-4 893-839-C Attaching the Terminal LeadsRequired tool: Flat-tip screwdriver1. Pry off the terminal safety cover with a flat-tip screwdriver.2. Loosen

Strona 55 - 893-839-C B-1

893-839-C B-5 5. Snap the safety cover back into place over the terminals.6. Attach the positive and negative terminal leads to the DC input power sou

Strona 56 - Safety Considerations

vi 893-839-C Chapter 4 Operating a Stack of Hubs Automatic Hub Configuration 4-1Swapping a Hub in a Stack 4-2Using the Communications Port

Strona 57 - To DC power ground

893-839-CBook Page 6 Thursday, December 12, 1996 4:18 PM

Strona 58 - Attaching the Terminal Leads

893-839-C Index-1 IndexNumerics10BASE2segment length maximum 3-3thin coaxial media adapter 1-2, 1-610BASE5segment length maximum 3-310BASE-FLfiber

Strona 59

Index-2 893-839-CIndexdata flow 2-6definition of 1-1information carried 1-16installing 2-7restrictions 2-6single repeater maximums 1-16Collision

Strona 60

893-839-C Index-3 Indexexpansion slot 1-16media adapter slot 1-6FOIRL, segment length maximum 3-3Hhot swapcascade cables 4-2NMM SmartSwap 4-1IInf

Strona 61 - Numerics

Index-4 893-839-CIndexlimitations 2-8SNMP management by 2-8Standard NMM management features 1-2statistics 1-2Ooperatingaltitude A-2conditions A-

Strona 62 - Index-2 893-839-C

893-839-C Index-5 IndexSsafety agency approvals A-2Seg 1-3, Isol (segment) LEDs 1-13segmentassignmentchanging 1-14, 2-8considerations 2-7in cascad

Strona 63 - 893-839-C Index-3

Index-6 893-839-CIndex893-839-CBook Page 6 Thursday, December 12, 1996 4:18 PM

Strona 64 - Index-4 893-839-C

893-839-C vii Figures Figure 1-1. Front panel of the BayStack Model 101 RJ-45 hub (functionally identical to the BayStack Model 106 − 48 Volt DC

Strona 65 - 893-839-C Index-5

-viii 893-839-C 893-839-CBook Page viii Thursday, December 12, 1996 4:18 PM

Strona 66 - Index-6 893-839-C

893-839-C xi Tables Table 1-1. BayStack 100-series hubs 1-4Table 1-2. Communications port pin and signal information 1-6Table 1-3. Comm