Using Syslog Messaging to Monitor Router Events
303561-A Rev 00
C-39
Parameter: Filter Operational State
Attribute Name: wfSyslogEntFltrOperState
Attribute Number: 6
Default: 2 (inactive filter)
Options: 1 (active filter)
|
2 (inactive filter)
Function: Indicates the actual status of the filter. When the status is ACTIVE,
Syslog filters against the criteria specified for this filter. When the state is
INACTIVE, Syslog does not use this filter to select and forward messages
to a remote host for one or more of the following reasons:
The filter’s host is not ACTIVE.
The filter does not have a configured event number or range.
The filter does not have a configured severity mask.
The filter slot numbers do not correspond to actual slot numbers on
this router model.
Instructions: Retrieve the value of this attribute when you want to check the status of a
filter for a specific entity.
Command:
get wfSyslogEntFltrEntry.wfSyslogEntFltrOperState
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.6